GE Plug-In Linkable LED Under-Cabinet Light, 18-Inch Warm White (93129098)
A cord-and-plug option for an 18-inch run. Compare the fixture length, switch placement and included lead with the route you measured.

Install plug-in under-cabinet LED lights with the right spacing, brackets and cord route. Reduce countertop glare and check fixture and link compatibility.
Follow these steps at your own pace. Check product terms and prices directly with providers before purchasing.
Place a cutting board on the counter and stand where you normally chop vegetables. If your hands disappear into your own shadow, another ceiling bulb may do little for that spot. A small light under the upper cabinet can illuminate the board directly. Where you put the first fixture matters just as much as how bright it is.
Quick Answer
Choose a listed under-cabinet system designed to plug into a suitable existing outlet. Lay out the fixtures and complete cord route before making holes. Mount the brackets in sound cabinet material using the hardware and clearances in the manual. With the wall plug out, lock in each fixture and join only the specified connectors. Plug in last, then check the counter from standing and seated positions. New receptacles, hardwiring and concealed building wiring belong with a qualified electrician.
Measure the usable underside of each cabinet rather than the entire kitchen wall. A face frame, recessed bottom, central divider or appliance garage can break a seemingly continuous run. Draw these breaks and note the underside trim depth. Add the work zones where light matters: breakfast preparation beside the toaster, the counter where you read labels, or the long stretch used for chopping.
Measure the cord path from the actual outlet location to the intended entry side of the first fixture. Include vertical changes and turns in the route. Check which side of the outlet a bulky plug occupies and whether you can still unplug it by hand. If the only available route crosses the sink, cooktop, doorway or a moving appliance, look for a different location or consult an electrician. Permanent extension-cord routing is a poor substitute for a nearby suitable receptacle.
Example: A nominal six-foot cabinet run could have two three-foot boxes separated by a vertical divider extending below the cabinet bottoms. A short, rigid joiner may be unusable there even though the lights fit each box. Trace the proposed link with string and check its path against the manufacturer's permitted connector, bend radius and cable support method before choosing the system.
| Fixture type | What it does well | Check before purchase |
|---|---|---|
| Separate puck lights | Concentrated pools on specific work areas | Beam overlap, number of permitted linked fixtures, visible reflections. |
| Linear bar or flat panel | More continuous wash along a prep counter | Rigid length, connector projection, end clearance and mounting clips. |
| LED tape in a compatible system | Fits some slim recesses and longer runs | Driver, permitted cut marks, mounting surface and listing for that location. |
This installation follows a plug-in puck or bar with factory connectors. Read the manual for the exact product family, input and exposure rating, permitted locations, maximum connected load or number of fixtures, and supplied mount. A connector that fits physically can still belong to a different voltage or system. Where the manufacturer lists particular link cords, use those lengths and part numbers. The instructions for adhesive LED tape, with its own driver and cutting rules, do not transfer to a sealed light bar.
Choose a finish and light color after looking at the counter. A polished stone worktop may show sharp, reflected dots from bright pucks. A fixture with a diffuser generally gives a softer reflection; a row of bars may suit a long glossy counter. Place the fixture far enough forward to light the task but behind the cabinet lip if that hides it from sight. A printed template lets you test these trade-offs on your own cabinetry.
Cut paper templates the size of the fixture body and bracket. Mark the connector ends, the switch location and any space needed to rotate or slide the housing onto its mount. Place the templates on the cabinet bottom with finish-safe removable tape. Stand at the counter, sit at a nearby table and look from the adjoining room. Seeing the bare fixture from a low chair can be a useful reason to move it back a little, so long as the work surface still receives light.
If the system permits a temporary operating test, assemble it on a safe, dry surface as instructed, before mounting, and keep its ventilation openings unobstructed. Do not hang a powered fixture by masking tape or let the plug or links rest against water or hot equipment. Unplug before repositioning or disconnecting. Mark the fixture positions that give useful coverage and photograph the paper layout with the cords laid out beside it.
Open the cabinet above the planned screws. Remove dishes and check the underside thickness, inside finish, shelf supports and screws already present. Common cabinet bottoms can be thinner than the face frame makes them appear. A bracket screw protruding into the cupboard can cut a hand or damage dishes. For a base cabinet with moving hardware nearby, check the full travel of pull-out shelves and their moving parts. Avoid fixing hardware where clearance cannot be established.
Gather a pencil, tape, ruler, hand screwdriver and the kit's supplied brackets and screws. Use a drill and controlled-depth pilot only if the manual calls for one and the cabinet material allows it. When you need help understanding clutch and depth control for another cabinet task, the cordless drill guide explains those features. Avoid substituting a longer screw just because it is in the toolbox. Ask the maker for an approved attachment method if the supplied arrangement cannot be used in your cabinet.
Mark each hole using the actual bracket with its orientation arrow or connector side facing correctly. Fit the bracket straight without deforming it. The Feit OneSync puck example uses a screw-mounted bracket: align its fixture keyholes and rotate the body as directed until locked. Other products slide onto a clip from one end, so leave the insertion path open. Check the fixture sits firmly without pulling on a cable for support.
Join the power lead and permitted linking cords while the wall plug is out. Match the keyed shapes and push in the direction the instructions show. A connector should seat cleanly without twisting or filing its key. Fit end covers if the kit calls for them. Inspect the route for sharp cabinet corners, hinges, slide mechanisms, oven vents and places where an appliance can push or trap a cord. If a link comes up short, use the approved longer link or revise the layout.
Secure the cable only with the approved retention method. Keep enough room at a connector to disconnect it for service without putting tension on its pins. Avoid staples through or across cords, cut-and-splice shortcuts, routing flexible cord inside walls, and bundling excess cable beside a hot appliance. Keep plugs and power supplies in their approved, accessible and ventilated positions. A kitchen switch or dimmer that worked with an older fixture may be incompatible with the new electronics; use controls approved for the new system.
Plug in the completed system last. Try all intended settings. Place a knife safely flat on the board, set down a white recipe page and look across a dark countertop from your usual positions. Strong white hotspots in the stone, a dark band between two pucks or shadows cast by your hands are specific reasons to reposition or change fixtures. Make any adjustment with the assembly unplugged.
Open cabinet doors and appliance doors fully. Slide countertop equipment into its normal position, leaving required clearances. Make sure cables stay clear and the lighting controls remain usable with items on the counter. For a separate cupboard or pantry where only a brief automatic light is needed, choosing and mounting a motion-sensor closet light covers a different setup. Do not assume a product listed for a closet can go over a sink or cooking surface.
Only the first fixture lights. Unplug the run and inspect the first dark unit's link, direction markings and relationship to the allowed system maximum. Test approved components individually if the instructions permit it. Never open a sealed power supply.
The lights flicker or go out when a cabinet door moves. Unplug and check for a pinched cable or partially seated link. Replace damaged parts with approved ones. If there is heat damage, an electrical odor, a loose outlet or a breaker trips, stop using the circuit and consult a qualified electrician.
The switch is hard to reach. Try the kitchen with appliances in their everyday places before routing cords permanently. Some kits have a remote option, but the power plug and any required controls still need service access.
Use an adhesive mount only when the manufacturer approves it for that fixture, surface and orientation. A strip sold for unrelated hooks may release under heat and drop the fixture onto the counter.
The beam pattern, mounting height, countertop reflectivity and task determine the spacing. Use the product's coverage guidance and a mock-up. A fixed interval copied from a different kitchen can leave dark gaps.
Only if the manufacturers explicitly list the components together. Otherwise choose matching fixtures and links from the approved system or power an independent listed system as intended.
Lay out the light from the cutting board outward. A run with a reachable outlet, visible work surface and concealed yet serviceable links will be easier to use every day than one placed solely to look symmetrical under the cabinets.
Manufacturer instructions: Feit Electric plug-in puck installation and Feit Electric plug-in light bar installation.
As an Amazon Associate, TeachMeHow earns from qualifying purchases.

A cord-and-plug option for an 18-inch run. Compare the fixture length, switch placement and included lead with the route you measured.

Measure the clear run behind the cabinet lip and the route to the receptacle before selecting bar and cord lengths.
Prices may change. Check the retailer for the current price and availability. We may earn a commission from qualifying purchases at no additional cost to you. Learn more.
Comments
Read or join the discussion.